IEC 60502 2 Cores - 5 Cores Mica Tape XLPE Insulated LSZH Bedded Galvanised Steel Wire Armoured LSZH Sheathed Power Cable

CU/MGT/XLPE/LSZH/SWA/LSZH (2 Cores - 5 Cores) Mica Tape, XLPE Insulated, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable Application These cables are suitable for indoor and outdoor applications, where a high safety against flame is required . Public address and emergency voice...

Product Details

CU/MGT/XLPE/LSZH/SWA/LSZH (2 Cores - 5 Cores)

Mica Tape, XLPE Insulated, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable


Application

These cables are suitable for indoor and outdoor applications, where a high safety against flame is required .

Public address and emergency voice communication system and traffic control centres.

Control and instrumentation service in industrial, commercial and residential buildings.

Such as: Schools&Universities, Hospital, Markets & Malls, Hotels, Theatres, Cinemas, Airports, Underground stations, Tunnels, Recreational places& Amusement parks, Indoor work places.

2core - insulation - sheath - swa - sheath.jpg

Construction

Conductor: Plain annealed copper, class1 solid or class 2 stranded acc. to IEC 60228.

Flexible class 5 or tinned conductor could be offer upon request.

Fire Barrier: Mica tape (MGT).

Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1.

Insulation Color Code:

Number of Cores Color Code to IEC 60502-1Color Code to BS 5467

2

Red & Black Brown & Blue
3Red, Yellow and BlueBrown, Black and Grey
4Red, Yellow, Blue and BlackBlue, Brown, Black and Grey
5

Red, Yellow, Blue, Black and

Green / Yellow

Green / Yellow, Blue, Brown,

Black and Grey

Assembly: Cores cabled together with PP filler and covered with non-woven tape.

Bedding: Low Smoke Zero Halogen (LSZH) Compound Type ST8 (90°C) of IEC 60502-1.

Bedding Colour: Black.

Armour: Galvanized steel wire armoured (SWA).

Outer Sheath: Low smoke zero halogen (LSZH) compound type ST1 (80°C), ST2 (90°C) of IEC 60502-1.

Outer Sheath Color: Orange or other color as per customer request.



Electrical Characteristics

Recommended rated voltages U


Highest system voltage

(U m ) (kV)

Rated voltage (U 0 ) (kV)
Categories A and B Category C
1.20.60.6

Routine test voltages

Rated voltage U 0 (kV) 0.6
Test voltage (kV)3.5

Maximum conductor temperatures for different types of insulating compound

Maximum conductor temperature (°C)
Normal operation Short-circuit (5 s maximum duration)
90250

Operating Temperature: -15°C to 90°C

Test Voltage: 3.5 kV for 5 minutes


Reference Standards

Design Specification: IEC60502-1

Conductor: IEC60228, BS EN60228

Fire Resistance: BS6387(C,W,Z), SS299(C,W,Z), IEC60331

Flame Retardancy: IEC60332-3-22, BS EN60332-3-22

Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2


Installation Reference

Min.Bending Radius (mm): 10 x cable overall diameter

Max.Pulling Tension (N/mm 2 ): 70


Dimension


2 Cores

Nominal Conductor Area (mm2)No.and Diameter of Wires (no./mm)Thickness of Insulation (mm)Thickness of Bedding (mm)Diameter Under Armour(mm)Diameter of Armour Wire (mm)Thickness of Sheath (mm)Overall Diameter (mm)Approximate Weight (kg/km)
2x1.57/0.530.719.80.81.815379
2x2.57/0.670.7110.61.251.816.7545
2x47/0.850.7111.71.251.817.8624
2x67/1.040.7112.81.251.818.9717
2x107/1.350.7114.71.251.820.8886
2x167/1.700.7116.81.61.823.61244
2x257/2.140.9120.21.61.8271627
2x357/2.520.9122.51.61.929.51967
2x5019/1.781125.62233.62652
2x7019/2.141.11.23022.138.23423
2x9519/2.521.11.233.822.342.44266
2x12037/2.031.21.437.82.52.447.65555
2x15037/2.251.41.441.72.52.651.96505
2x18537/2.521.61.446.32.52.756.77713
2x24061/2.251.71.652.32.5363.39578
2x30061/2.521.81.657.62.53.168.811376
2x40061/2.8521.864.73.153.477.814918
2x50061/3.202.21.871.83.153.785.517952
2x630127/2.522.41.880.53.15494.822069
2x800127/2.852.6290.33.154.3105.227146
2x1000127/3.202.82100.23.154.7115.932996

3 Cores

Nominal Conductor Area (mm2)No.and Diameter of Wires (no./mm)Thickness of Insulation (mm)Thickness of Bedding (mm)Diameter Under Armour(mm)Diameter of Armour Wire (mm)Thickness of Sheath (mm)Overall Diameter (mm)Approximate Weight (kg/km)
3x1.57/0.530.7110.41.251.816.5540
3x2.57/0.670.7111.31.251.817.4611
3x47/0.850.7112.41.251.818.5712
3x67/1.040.7113.71.251.819.8832
3x107/1.350.7115.71.61.822.51186
3x167/1.700.7117.91.61.824.71494
3x257/2.140.9121.61.61.828.42001
3x357/2.520.9124.11.61.931.12459
3x5019/1.7811.227.822.1363379
3x7019/2.141.11.232.122.240.54363
3x9519/2.521.11.236.22.52.4465937
3x12037/2.031.21.440.52.52.550.57143
3x15037/2.251.41.444.72.52.755.18434
3x18537/2.521.61.6502.52.960.810204
3x24061/2.251.71.656.12.53.167.312656
3x30061/2.521.81.661.73.153.374.616105
3x40061/2.8521.869.43.153.682.919827
3x50061/3.202.21.877.13.153.991.224061
3x630127/2.522.4286.83.154.2101.529971
3x800127/2.852.6296.93.154.6112.437036
3x1000127/3.202.82107.63.154.9123.745272

4 Cores

Nominal Conductor Area (mm2)No.and Diameter of Wires (no./mm)Thickness of Insulation (mm)Thickness of Bedding (mm)Diameter Under Armour(mm)Diameter of Armour Wire (mm)Thickness of Sheath (mm)Overall Diameter (mm)Approximate Weight (kg/km)
4x1.57/0.530.7111.41.251.817.5608
4x2.57/0.670.7112.41.251.818.5695
4x47/0.850.7113.71.251.819.8821
4x67/1.040.7115.11.61.821.91098
4x107/1.350.7117.31.61.824.11393
4x167/1.700.7119.91.61.826.71781
4x257/2.140.91241.61.9312434
4x357/2.520.9126.82234.83267
4x5019/1.7811.230.922.239.34134
4x7019/2.141.11.235.72.52.445.55823
4x9519/2.521.11.440.72.52.550.77402
4x12037/2.031.21.445.12.52.755.58891
4x15037/2.251.41.650.22.52.96110620
4x18537/2.521.61.655.72.53.166.912801
4x24061/2.251.71.662.53.153.475.616907
4x30061/2.521.81.869.23.153.682.720405
4x40061/2.8521.877.33.153.991.425088
4x50061/3.202.2286.33.154.210130691
4x630127/2.522.4296.83.154.6112.338271
4x800127/2.852.62108.23.155124.547462
4x1000127/3.202.82120.13.155.4137.258272

5 Cores

Nominal Conductor Area (mm2)No.and Diameter of Wires (no./mm)Thickness of Insulation (mm)Thickness of Bedding (mm)Diameter Under Armour(mm)Diameter of Armour Wire (mm)Thickness of Sheath (mm)Overall Diameter (mm)Approximate Weight (kg/km)
5x1.57/0.530.7112.51.251.818.6680.8
5x2.57/0.670.7113.61.251.819.7784.3
5x47/0.850.7115.11.61.821.91062.4
5x67/1.040.7116.61.61.823.41252.3
5x107/1.350.7119.11.61.825.91607.6
5x167/1.700.71221.61.828.82076.5
5x257/2.140.9126.62234.63127.7
5x357/2.520.91.230.122.138.33916.6
5x5019/1.7811.234.322.342.94909.7
5x7019/2.141.11.440.12.52.550.16984.4
5x9519/2.521.11.445.22.52.755.68863.6
5x12037/2.031.21.650.52.52.961.310758.9
5x15037/2.251.41.655.72.53.166.912783.6
5x18537/2.521.61.661.93.153.374.816349.9
5x24061/2.251.71.869.93.153.683.420482.6
5x30061/2.521.81.8773.153.991.124698.4
5x40061/2.852286.53.154.2101.230571.5
5x50061/3.202.2296.13.154.5111.437322.7
5x630127/2.522.42107.83.154.9123.946653.7
5x800127/2.852.62120.53.155.4137.658048.8
5x1000127/3.202.82133.93.155.9

152

71469.4
Supplying you with customized iec 60502 2 cores - 5 cores mica tape xlpe insulated lszh bedded galvanised steel wire armoured lszh sheathed power cable, it is one of the reliable iec 60502 2 cores - 5 cores mica tape xlpe insulated lszh bedded galvanised steel wire armoured lszh sheathed power cable manufacturers and suppliers, welcome to wholesale our products at good price from our factory.