Single Core Cables To IEC 60502

Single Core Cables To IEC 60502

Supplying you with customized single core cables to iec 60502, it is one of the reliable single core cables to iec 60502 manufacturers and suppliers, welcome to wholesale our products at good price from our factory. Single Core Medium Cable to IEC 60502-2 Table 1. Insulation Thickness Of XLPE Or...

Product Details

Supplying you with customized single core cables to iec 60502, it is one of the reliable single core cables to iec 60502 manufacturers and suppliers, welcome to wholesale our products at good price from our factory.

Single Core Medium Cable to IEC 60502-2

Application:

The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

Standards:

IEC 60502 Part 1(1.8/3KV)
IEC 60502 Part 2(3.6/6KV to 18/30KV

Conductor:

Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2).

Conductor Screen:

The conductor screen consists of an extruded layer of non metallic, semi-conducting compound firmly bonded to the insulation to exclude all air voids. The conductor screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3KV and 3.6/6KV cables.

Insulation:

Insulation is of polyvinyl chloride (PVC) intended for 1.8/3KV and 3.6/6KV cables, cross-linked polyethylene compound (XLPE) or ethylene propylene rubber (EPR/HEPR).

Table 1. Insulation Thickness Of XLPE Or EPR/HEPR Insulation


     Nom. CrossSection Area

Insulation Thickness at Nominal Voltage

1.8/3KV (Um=3.6KV)

3.6/6KV 

      (Um=7.2KV)

6/10KV (Um=12KV)

8.7/15KV (Um=17.5KV)

12/20KV (Um=24KV)

18/30KV (Um=36KV)

21/35KV (Um=42KV)

26/35KV (Um=42KV)

mm2

mm

mm

mm

mm

mm

mm

mm

mm


XLPE/EPR

XLPE

EPR

XLPE/EPR

XLPE/EPR

XLPE/EPR

XLPE/EPR

XLPE/EPR

XLPE/EPR


Unscreened

Screened

10

2.0

2.5

3.0

2.5

-

-

-

-

-

-

16

2.0

2.5

3.0

2.5

3.4

-

-

-

-

-

25

2.0

2.5

3.0

2.5

3.4

4.5

-

-

-

-

35

2.0

2.5

3.0

2.5

3.4

4.5

5.5

-

-

-

50 – 185

2.0

2.5

3.0

2.5

3.4

4.5

5.5

8.0

9.3

10.5

240

2.0

2.6

3.0

2.6

3.4

4.5

5.5

8.0

9.3

10.5

300

2.0

2.8

3.0

2.8

3.4

4.5

5.5

8.0

9.3

10.5

400

2.0

3.0

3.0

3.0

3.4

4.5

5.5

8.0

9.3

10.5

500 - 1600

2.2-2.8

3.2

3.2

3.2

3.4

4.5

5.5

8.0

9.3

10.5

*Insulation Thickness of PVC is 3.4mm (1- 1600mm sq) for 3.6/6KV cables.

Insulaton Screen: The insulation screen consists of an extruded layer of non metallic, semi- conducting compound extruded over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site. The insulation screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3KV and 3.6/6KV cables. The screen may be covered by semi-conductive water blocking swellable tape to ensure longitudinal watertightness.Metallic Layer: The metallic layer may be applied over the individual cores or the core assembly collectively.The following types of metallic layers are provided:1) Metallic Screen2) Concentric Conductor3) Metallic Sheath4) Metallic armourThe metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires to provide an earth fault current path. The concentric conductor is applied directly either over the insulation, or over the insulation screen or over an inner covering. The metallic sheath consists of lead or lead alloy applied as a tightly fitting seamless tube. The metallic armour consists of either flat wire armour, round wire armour, and double tape armour.

Table 2. Minimum Total Cross Section Of Metallic Screen

Nom. Cross-Section Area of Cable

Min. Cross-Section of Metallic Screen

DC Resistance of the Copper Wire Screen

mm²

mm²

mm

up to 120

16

1.06

150-300

25

0.72

400-630

35

0.51

800-1000

50

0.35

Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. For cables without a lead sheath, the nominal separation sheath thickness shall not be less than 1.2mm. For cables where the separation sheath is applied over the lead sheath, the nominal separation sheath thickness shall not be less than 1.0mm.Lapped Bedding (for armoured lead sheathed cable): The lapped bedding consists of either impregnated/synthetic compounded paper tapes or a combination of two layers of these paper tapes followed by a few layers of compounded fabulous materials. The thickness is around 1.5mm.Armour (for armoured cable): The armour consists of round aluminium wire armour applied helically over an extruded separation sheath.Table 3. Round Armour Wire Diameter 

Fictitious Diameter Under the Armour

Armour Wire Diameter

mm

mm

>

<< p="">


-

10

0.8

10

15

1.25

15

25

1.6

25

35

2.0

35

60

2.5

60

-

3.15

Over Sheath: Overall sheath comprises a layer of extruded thermoplastic compound (PVC, PE or LSZH can be offered as an option.) or elastomeric compound (polychlorprene CSP or chlorosulfonated PE). The nominal oversheath thickness is calculated by 0.035D+1 where D is the fictitiuous diameter immediately under the oversheath in mm. For unarmoured cables and cables with the oversheath not applied over the armour, metallic screen or concentric conductor, the nominal oversheath thickness shall not be less than 1.4mm. And for cables with oversheath applied over the armour, metallic screen or concentric conductor, the nominal oversheath thickness shall not be less than 1.8mm.
PHYSICAL PROPERTIES:
Operating Temperature: up to 70°C (PVC insulation); up to 90°C (XLPE or EPR insulation)Temperature Range: -5°C ( PVC sheath ); -20°C ( PE sheath )Short Circuit Temperature( 5 seconds maximum duration ): 140-160°C (PVC insulation);250°C (XLPE or EPR insulation)Bending Radius: 12 x OD
Table 4. Nominal /Operating /Testing Voltages

Rated Voltage Uo/U

Operating Voltage (Um)

Testing Voltage (rms)

1.8/3KV

3.6KV

6.5KV

3.6/6KV

7.2KV

12.5KV

6/10KV

12KV

21KV

8.7/15KV

17.5KV

30.5KV

12/20KV

24KV

42KV

18/30KV

36KV

63KV

21/35KV

42KV

73.5(53)*KV

26/35KV

42KV

91(65)*KV

*21/35KV and 26/35kV power frequency voltage test can be made under the following conditions: 2.5Uo x 30mins or 3.0Uo x 15mins. Numbers in brackets refer to the test values for 3.0Uo x 1.5mins.
Single Core 1.8/3KV (Um=3.6KV) Dimensional Data

Nom. Cross-Section Area


Unarmoured Cables

Steel Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

CU

AL

CU

AL

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

10

2.0

0.1

16

1.8

13

240

180

1.2

1.6

1.8

18

460

400

16

2.0

0.1

16

1.8

13

300

200

1.2

1.6

1.8

19

530

430

25

2.0

0.1

16

1.8

15

410

250

1.2

1.6

1.8

20

650

500

35

2.0

0.1

16

1.8

16

510

300

1.2

1.6

1.8

21

780

560

50

2.0

0.1

16

1.8

17

640

350

1.2

1.6

1.8

22

930

640

70

2.0

0.1

16

1.8

19

850

440

1.2

1.6

1.8

24

1170

750

95

2.0

0.1

16

1.8

20

1130

540

1.2

1.6

1.8

26

1460

870

120

2.0

0.1

16

1.8

22

1370

630

1.2

1.6

1.8

27

1730

990

150

2.0

0.1

25

1.8

23

1650

730

1.2

1.6

1.8

29

2030

1110

185

2.0

0.1

25

1.8

25

2010

860

1.2

1.6

1.9

30

2430

1280

240

2.0

0.1

25

1.8

27

2570

1050

1.2

1.6

2.0

33

3040

1530

300

2.0

0.1

25

1.8

29

3160

1250

1.2

2.0

2.1

36

3760

1860

400

2.0

0.1

35

1.9

33

3980

1560

1.2

2.0

2.2

39

4660

2230

500

2.2

0.1

35

2.1

35.5

4910

1905

1.3

2.5

2.5

43

5930

2930

630

2.4

0.1

35

2.2

39.7

6340

2420

1.4

2.5

2.6

49

7370

3430

800

2.6

0.1

50

2.3

44.5

7890

2980

1.4

2.5

2.7

52

9070

4230

1000

2.8

0.1

50

2.5

49.4

9890

3700

1.5

2.5

2.9

56

11100

4950

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A C Resistance CU / AL

Short Circuit Rating of Conductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Rating of Copper Wire Screen1 sec

Short Circuit Rating of Copper Tape Screen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat Spaced

Trefoil

Flat Spaced

Trefoil

Flat Spaced

cu

AL

cu

AL

mm2

μΩ/m

μΩm

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/ m

μΩ/ m

10

1830/3080

2330/3920

1.4/0.9

182

0.27

2.6

0.2

151

201

384

558

2332

3846

2332

3840

16

1150/1910

1460/2420

2.2/1.4

201

0.29

2.6

0.3

140

193

362

546

1462

2411

1478

2420

25

727/1200

927/1538

3.6/2.3

222

0.32

2.6

0.3

131

185

345

535

936

1544

952

1554

35

524/868

668/1113

5.0/3.2

251

0.35

2.6

0.4

122

178

327

524

679

1121

695

1131

50

387/641

494/822

6.8/4.4

281

0.39

2.6

0.4

116

172

313

514

511

834

527

844

70

268/443

343/568

9.8/6.3

341

0.45

2.6

0.5

110

165

300

495

364

583

386

597

95

193/320

248/410

13.3/8.5

397

0.50

2.6

0.5

104

160

287

485

272

427

300

446

120

153/253

196/325

17.2/11.0

430

0.55

2.6

0.6

104

159

283

480

225

345

257

367

150

124/206

159/266

21.2/13.5

464

0.59

4.3

0.6

100

156

280

475

193

287

229

313

185

99.1/164

128/211

26.6/17.0

513

0.65

4.3

0.7

98

154

274

465

165

237

206

267

240

75.4/125

98/161

34.9/22.3

573

0.70

4.3

0.9

94

150

267

459

140

191

185

226

300

60.1/100

80/130

43.8/28.0

652

0.72

4.3

1.0

91

147

260

455

128

163

174

203

400

47.0/77.8

64/102

57.3/36.6

727

0.75

5.8

1.1

90

147

253

445

113

141

164

184

500

36.6/60.5

51/81

72.3/46.2

754

0.79

5.8

1.2

89

145

248

435

105

124

158

171

630

28.3/46.9

42/64

91.2/58.3

786

0.87

5.8

1.3

86

143

245

425

97

110

151

160

800

22.1/36.7

35/55

114.4/75.0

846

0.91

8.2

1.4

85

142

243

415

92

101

147

153

1000

17.6/29.1

30/46

143.0/94.0

916

0.99

8.2

1.5

83

141

239

405

88

95

144

148

Single Core 3.6/6KV (Um=7.2KV) Dimensional Data


 Nom. Cross-Section Area


Unarmoured Cables

Aluminium Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom .Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

CU

AL

CU

AL

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

10

2.5

0.1

16

1.8

16

320

260

1.2

1.6

1.8

22

610

550

16

2.5

0.1

16

1.8

16

390

290

1.2

1.6

1.8

22

680

580

25

2.5

0.1

16

1.8

18

500

340

1.2

1.6

1.8

23

810

660

35

2.5

0.1

16

1.8

19

610

400

1.2

1.6

1.8

24

940

730

50

2.5

0.1

16

1.8

20

750

450

1.2

1.6

1.8

26

1100

810

70

2.5

0.1

16

1.8

22

970

550

1.2

1.6

1.8

27

1350

930

95

2.5

0.1

16

1.8

23

1250

660

1.2

1.6

1.9

29

1670

1080

120

2.5

0.1

16

1.8

25

1500

760

1.2

1.6

1.9

31

1950

1200

150

2.5

0.1

25

1.8

26

1790

860

1.2

1.6

2.0

32

2270

1350

185

2.5

0.1

25

1.8

28

2150

1000

1.2

2.0

2.1

35

2770

1620

240

2.6

0.1

25

1.9

31

2770

1250

1.2

2.0

2.2

38

3440

1930

300

2.8

0.1

25

2.0

34

3400

1500

1.2

2.0

2.2

41

4120

2210

400

3.0

0.1

35

2.1

38

4280

1850

1.3

2.5

2.4

46

5250

2820

500

3.2

0.1

35

2.1

41.5

5325

2240

1.4

2.5

2.6

50

6520

3520

630

3.2

0.1

35

2.2

45.3

6745

2750

1.5

2.5

2.7

56

7960

4020

800

3.2

0.1

50

2.4

49.9

8290

3310

1.5

2.5

2.8

59

9660

4820

1000

3.2

0.1

50

2.5

54.2

10255

3990

1.6

2.5

3.0

63

11690

5540

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A C Resistance CU / AL

Short Circuit Rating ofConductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Ratingof Copper Wire Screen1 sec

Short Circuit Ratingof Copper TapeScreen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat Spaced

Trefoil

Flat Spaced

Trefoil

Flat Spaced

CU

AL

CU

AL

mm2

μΩ/m

μΩm

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/m

μΩ/m

10

1830/3080

2330/3920

1.4/0.9

202

0.26

2.6

0.4

160

214

420

610

2332

3846

2345

3840

16

1150/1910

1460/2420

2.2/1.4

232

0.29

2.6

0.4

152

205

410

600

1462

2411

1478

2421

25

727/1200

927/1538

3.6/2.3

262

0.32

2.6

0.4

142

196

400

590

936

1544

952

1554

35

524/868

668/1113

5.0/3.2

291

0.35

2.6

0.5

133

187

390

580

679

1121

695

1131

50

387/641

494/822

6.8/4.4

321

0.39

2.6

0.5

121

179

380

570

511

834

527

844

70

268/443

343/568

9.8/6.3

371

0.45

2.6

0.6

115

173

370

550

364

583

386

597

95

193/320

248/410

13.3/8.5

417

0.50

2.6

0.6

110

168

350

540

272

427

300

446

120

153/253

196/325

17.2/11.0

459

0.55

2.6

0.7

107

165

340

520

225

345

257

367

150

124/206

159/265

21.2/13.5

494

0.59

4.3

0.7

103

161

330

510

193

287

229

313

185

99.1/164

128/211

26.6/17.0

543

0.65

4.3

0.8

100

158

320

500

165

237

206

267

240

75.4/125

98/161

34.9/22.3

583

0.70

4.3

0.9

97

155

310

490

140

191

185

226

300

60.1/100

80/130

43.8/28.0

602

0.72

4.3

1.0

95

153

300

490

126

163

174

203

400

47.0/77.8

64/102

57.3/36.6

627

0.75

5.8

1.1

92

150

290

480

113

141

164

184

500

36.6/60.5

51/81

72.3/46.2

654

0.79

5.8

1.2

90

147

290

470

105

124

158

171

630

28.3/46.9

42/64

91.2/58.3

726

0.87

5.8

1.3

87

145

280

460

97

110

151

160

800

22.1/36.7

35/55

114.4/75.0

786

0.91

8.2

1.4

85

143

270

460

92

101

147

153

1000

17.6/29.1

30/46

143.0/94.0

856

0.99

8.2

1.5

83

141

260

450

88

95

144

148

Single Core 6/10KV (Um=12KV) Dimensional Data


 Nom. Cross-Section Area


Unarmoured Cables

Aluminium Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

CU

AL

CU

AL

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

16

3.4

0.1

16

1.8

18

450

350

1.2

1.6

1.8

24

770

670

25

3.4

0.1

16

1.8

20

560

400

1.2

1.6

1.8

25

910

750

35

3.4

0.1

16

1.8

21

680

460

1.2

1.6

1.8

26

1040

820

50

3.4

0.1

16

1.8

22

810

520

1.2

1.6

1.8

28

1190

900

70

3.4

0.1

16

1.8

24

1050

620

1.2

1.6

1.9

29

1470

1040

95

3.4

0.1

16

1.8

25

1320

730

1.2

1.6

2.0

31

1780

1190

120

3.4

0.1

16

1.8

27

1580

840

1.2

2.0

2.0

34

2150

1410

150

3.4

0.1

25

1.9

28

1880

960

1.2

2.0

2.1

35

2480

1560

185

3.4

0.1

25

1.9

30

2250

1100

1.2

2.0

2.1

37

2890

1730

240

3.4

0.1

25

2.0

33

2870

1350

1.2

2.0

2.2

40

3570

2050

300

3.4

0.1

25

2.1

35

3490

1580

1.2

2.0

2.3

42

4230

2330

400

3.4

0.1

35

2.2

39

4350

1920

1.3

2.5

2.4

47

5320

2890

500

3.4

0.1

35

2.2

39.9

5235

2240

1.4

2.5

2.5

51

6510

3530

630

3.4

0.1

35

2.3

43.7

6675

2765

1.5

2.5

2.6

56

7960

4050

800

3.4

0.1

50

2.5

48.6

8225

3330

1.5

2.5

2.7

59

9670

4850

1000

3.4

0.1

50

2.6

52.9

10210

4030

1.6

2.5

2.9

63

11710

5570

* For capacitance & charging current values, multiply values shown by 1.2 for EPR insulated cables.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A C Resistance CU / AL

ShortCircuit Rating ofConductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Rating of Copper Wire Screen1 sec

Short Circuit Rating of Copper Tape Screen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat Spaced

Trefoil

Flat Spaced

Trefoil

Flat spaced

CU

AL

CU

AL

mm2

μΩ/m

μΩm

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/m

μΩ/m

16

1150/1910

1460/2420

2.2/1.4

187

0.39

2.6

0.5

152

216

480

680

1462

2411

1478

2421

25

727/1200

927/1538

3.6/2.3

208

0.42

2.6

0.5

144

210

460

660

936

1544

952

1554

35

524/868

668/1113

5.0/3.2

229

0.46

2.6

0.6

136

200

440

640

679

1121

695

1131

50

387/641

494/822

6.8/4.4

252

0.50

2.6

0.6

131

195

420

620

511

834

527

844

70

268/443

343/568

9.8/6.3

288

0.58

2.6

0.7

122

188

390

600

364

583

386

597

95

193/320

248/410

13.3/8.5

323

0.65

2.6

0.7

122

182

390

580

272

427

300

446

120

153/253

196/325

17.2/11.0

353

0.71

2.6

0.8

116

172

370

550

225

345

257

367

150

124/206

159/265

21.2/13.5

380

0.76

4.3

0.8

110

166

350

530

193

287

229

313

185

99.1/164

128/211

26.6/17.0

416

0.83

4.3

0.9

107

166

340

530

165

237

206

267

240

75.4/125

98/161

34.9/22.3

460

0.92

4.3

0.9

104

163

330

520

140

191

185

226

300

60.1/100

80/130

43.8/28.0

506

1.01

4.3

1.0

100

157

320

500

126

163

174

203

400

47.0/77.8

64/102

57.3/36.6

561

1.12

5.8

1.1

94

154

300

490

113

141

164

184

500

36.6/60.5

51/81.0

72.3/46.2

619

1.24

5.8

1.2

91

151

290

480

105

124

158

171

630

28.3/46.9

42/64.0

91.2/58.3

698

1.37

5.8

1.3

91

148

290

470

97

110

151

160

800

22.1/36.7

35/55

114.4/75.0

780

1.39

8.2

1.4

88

144

280

470

92

101

147

153

1000

17.6/29.1

30/46

143.0/94.0

860

1.54

8.2

1.5

85

143

270

460

88

95

144

148

* For capacitance & charging current values, multiply values shown by 1.2 for EPR insulated cables.
Single Core 8.7/15KV (Um=17.5KV) Dimensional Data

Nom. Cross-Section Area


Unarmoured Cables

Aluminium Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

CU

AL

CU

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

25

4.5

0.1

16

1.8

22

640

480

1.2

1.6

1.8

28

1020

35

4.5

0.1

16

1.8

23

760

540

1.2

1.6

1.9

29

1170

50

4.5

0.1

16

1.8

24

900

610

1.2

1.6

1.9

30

1340

70

4.5

0.1

16

1.8

26

1140

710

1.2

1.6

2.0

32

1610

95

4.5

0.1

16

1.8

27

1420

830

1.2

2.0

2.1

35

2020

120

4.5

0.1

16

1.9

29

1700

950

1.2

2.0

2.1

36

2310

150

4.5

0.1

25

1.9

31

1990

1070

1.2

2.0

2.2

38

2660

185

4.5

0.1

25

2.0

32

2380

1230

1.2

2.0

2.2

39

3070

240

4.5

0.1

25

2.1

35

3010

1490

1.2

2.0

2.3

42

3750

300

4.5

0.1

25

2.1

37

3620

1720

1.3

2.5

2.4

46

4590

400

4.5

0.1

35

2.2

41

4490

2070

1.3

2.5

2.5

49

5550

500

4.5

0.1

35

2.3

43

5460

2460

1.3

2.5

2.6

52

6590

630

4.5

0.1

35

2.4

48

6790

2590

1.4

2.5

2.7

57

8060

800

4.5

0.1

50

2.6

52

8420

3570

1.5

2.5

2.8

61

9800

1000

4.5

0.1

50

2.7

55

10330

4180

1.6

2.5

3.0

65

10850

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A C Resistance CU / AL

ShortCircuit Rating ofConductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Rating of Copper Wire Screen1 sec

Short Circuit Rating of Copper Tape Screen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat Spaced

Trefoil

Flat Spaced

Trefoil

Flat spaced

CU

AL

CU

AL

mm2

μΩ/m

μΩm

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/m

μΩ/m

25

727/1200

927/1538

3.6/2.3

171

0.47

2.6

0.6

150

210

480

680

936

1544

952

1554

35

524/868

668/1113

5.0/3.2

187

0.51

2.6

0.6

141

207

460

660

679

1121

695

1131

50

387/641

494/822

6.8/4.4

204

0.57

2.6

0.7

138

195

440

640

511

834

527

844

70

268/443

343/568

9.8/6.3

232

0.63

2.6

0.7

132

188

420

600

364

583

386

597

95

193/320

248/410

13.3/8.5

258

0.71

2.6

0.8

126

182

400

580

272

427

300

446

120

153/253

196/325

17.2/11.0

281

0.74

2.6

0.8

119

179

380

570

225

345

257

367

150

124/206

159/265

21.2/13.5

301

0.79

4.3

0.9

113

176

360

560

193

287

229

313

185

99.1/164

128/211

26.6/17.0

329

0.87

4.3

0.9

110

170

350

540

165

237

206

267

240

75.4/125

98/161

34.9/22.3

363

0.96

4.3

1.0

107

166

340

530

140

191

185

226

300

60.1/100

80/130

43.8/28.0

398

1.03

4.3

1.1

104

160

330

510

126

163

174

203

400

47.0/77.8

64/102

57.3/36.6

439

1.17

5.8

1.2

97

157

310

500

113

141

164

184

500

36.6/60.5

51/81

72.3/46.2

483

1.28

5.8

1.3

94

154

300

490

105

124

158

171

630

28.3/46.9

42/64

91.2/58.3

534

1.42

5.8

1.4

91

151

290

480

97

110

151

160

800

22.1/36.7

35/55

114.4/75.0

590

1.61

8.2

1.4

91

147

290

470

92

101

147

153

1000

17.6/29.1

30/46

143.0/94.0

640

1.75

8.2

1.5

88

144

280

460

88

95

144

148

Single Core 12/20KV (Um=24KV) Dimensional Data


 Nom. Cross-Section Area


Unarmoured Cables

Aluminium Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

AL

Cu

AL

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

25

5.5

0.1

16

1.8

24

720

560

1.2

1.6

1.8

29

1200

980

35

5.5

0.1

16

1.8

25

840

620

1.2

1.6

1.9

30

1350

1070

50

5.5

0.1

16

1.8

26

990

690

1.2

2.0

2.0

33

1550

1250

70

5.5

0.1

16

1.8

28

1230

800

1.2

2.0

2.1

35

1840

1420

95

5.5

0.1

16

1.9

30

1530

940

1.2

2.0

2.1

37

2160

1570

120

5.5

0.1

16

2.0

31

1810

1050

1.2

2.0

2.2

38

2470

1730

150

5.5

0.1

25

2.0

33

2110

1190

1.2

2.0

2.2

40

2810

1890

185

5.5

0.1

25

2.1

35

2510

1360

1.2

2.0

2.3

42

3240

2090

240

5.5

0.1

25

2.1

38

3130

1610

1.3

2.5

2.4

45

4150

2580

300

5.5

0.1

25

2.2

40

3760

1860

1.3

2.5

2.5

48

4800

2890

400

5.5

0.1

35

2.3

43

4650

2220

1.4

2.5

2.6

52

5780

3350

500

5.5

0.1

35

2.4

46

5530

2545

1.5

2.5

2.7

55

6850

3850

630

5.5

0.1

35

2.5

50

6700

3100

1.5

2.5

2.9

60

8380

4400

800

5.5

0.1

50

2.6

55

8580

3690

1.6

2.5

3.0

64

10130

5270

1000

5.5

0.1

50

2.7

59

10620

4445

1.7

2.5

3.1

68

12180

6000

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A C Resistance CU / AL

ShortCircuit Rating ofConductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Rating of Copper Wire Screen1 sec

Short Circuit Rating of Copper Tape Screen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat Spaced

Trefoil

Flat Spaced

Trefoil

Flat spaced

Cu

AL

Cu

AL

mm2

μΩ/m

μΩm

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/ m

μΩ/m

25

727/1200

927/1538

3.6/2.3

142

0.62

2.6

0.6

162

214

490

680

936

1544

952

1554

35

524/868

668/1113

5.0/3.2

162

0.65

2.6

0.7

150

207

470

660

679

1121

695

1131

50

387/641

494/822

6.8/4.4

177

0.71

2.6

0.8

141

201

450

640

511

834

527

844

70

268/443

343/568

9.8/6.3

200

0.80

2.6

0.8

135

195

430

620

364

583

386

597

95

193/320

248/410

13.3/8.5

222

0.89

2.6

0.9

129

188

410

600

272

427

300

446

120

153/253

196/325

17.2/11.0

241

0.96

2.6

0.9

122

182

390

580

225

345

257

367

150

124/206

159/265

21.2/13.5

257

1.03

4.3

1.0

116

176

370

560

193

287

229

313

185

99.1/164

128/211

26.6/17.0

280

1.12

4.3

1.0

116

173

370

550

165

237

206

267

240

75.4/125

98/161

34.9/22.3

307

1.23

4.3

1.1

110

170

350

540

140

191

185

226

300

60.1/100

80/130

43.8/28.0

336

1.34

4.3

1.2

107

166

340

530

126

163

174

203

400

47.0/77.8

64/102

57.3/36.6

370

1.48

5.8

1.3

100

160

320

510

113

141

164

184

500

36.6/60.5

51/81

72.3/46.2

406

1.62

5.8

1.4

97

154

310

490

105

124

158

171

630

28.3/46.9

42/64

91.2/58.3

449

1.80

5.8

1.5

94

151

300

480

97

110

151

160

800

22.1/36.7

35/55

114.4/75.0

490

1.85

8.2

1.6

91

151

290

480

92

101

147

153

1000

17.6/29.1

30/46

143.0/94.0

540

2.03

8.2

1.7

87

148

280

470

88

95

144

148

* For capacitance & charging current values, multiply values shown by 1.2 for EPR insulated cables.
Single Core 18/30KV (Um=24KV) Dimensional Data

Nom. Cross-Section Area


Unarmoured Cables

Aluminium Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

AL

Cu

AL

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

25

5.5

0.1

16

1.8

24

720

560

1.2

1.6

1.8

29

1200

980

35

5.5

0.1

16

1.8

25

840

620

1.2

1.6

1.9

30

1350

1070

50

5.5

0.1

16

1.8

26

990

690

1.2

2.0

2.0

33

1550

1250

70

5.5

0.1

16

1.8

28

1230

800

1.2

2.0

2.1

35

1840

1420

95

5.5

0.1

16

1.9

30

1530

940

1.2

2.0

2.1

37

2160

1570

120

5.5

0.1

16

2.0

31

1810

1050

1.2

2.0

2.2

38

2470

1730

150

5.5

0.1

25

2.0

33

2110

1190

1.2

2.0

2.2

40

2810

1890

185

5.5

0.1

25

2.1

35

2510

1360

1.2

2.0

2.3

42

3240

2090

240

5.5

0.1

25

2.1

38

3130

1610

1.3

2.5

2.4

45

4150

2580

300

5.5

0.1

25

2.2

40

3760

1860

1.3

2.5

2.5

48

4800

2890

400

5.5

0.1

35

2.3

43

4650

2220

1.4

2.5

2.6

52

5780

3350

500

5.5

0.1

35

2.4

46

5530

2545

1.5

2.5

2.7

55

6850

3850

630

5.5

0.1

35

2.5

50

6700

3100

1.5

2.5

2.9

60

8380

4400

800

5.5

0.1

50

2.6

55

8580

3690

1.6

2.5

3.0

64

10130

5270

1000

5.5

0.1

50

2.7

59

10620

4445

1.7

2.5

3.1

68

12180

6000

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A CResistance CU / AL

ShortCircuit Rating of Conductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Rating of Copper Wire Screen1 sec

Short Circuit Rating of Copper Tape Screen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat spaced

Trefoil

Flat spaced

Trefoil

Flat spaced

Cu

AL

Cu

AL

mm2

μΩ/m

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/ m

μΩ/ m

50

387/641

494/822

6.8/4.4

138

0.83

2.6

1.0

151

214

480

680

511

834

527

844

70

268/443

343/568

9.8/6.3

154

0.92

2.6

1.0

144

201

460

640

364

583

386

597

95

193/320

248/410

13.3/8.5

169

1.01

2.6

1.1

138

195

440

620

272

427

300

446

120

153/253

196/325

17.2/11.0

183

1.10

2.6

1.1

132

188

420

600

225

345

257

367

150

124/206

159/265

21.2/13.5

194

1.16

4.3

1.2

126

182

400

580

193

287

229

313

185

99.1/164

128/211

26.6/17.0

210

1.26

4.3

1.2

122

182

390

580

165

237

206

267

240

75.4/125

98/161

34.9/22.3

229

1.37

4.3

1.3

119

176

380

560

140

191

185

226

300

60.1/100

80/130

43.8/28.0

249

1.49

4.3

1.4

113

173

360

550

126

163

174

203

400

47.0/77.8

64/102

57.3/36.6

273

1.64

5.8

1.5

107

163

340

520

113

141

164

184

500

36.6/60.5

51/81

72.3/46.2

298

1.79

5.8

1.6

104

163

330

520

105

124

158

171

630

28.3/46.9

42/64

91.2/58.3

327

1.96

5.8

1.7

100

160

320

510

97

110

151

160

800

22.1/36.7

35/55

114.4/75.0

350

1.98

8.2

1.8

97

154

310

490

92

101

147

153

1000

17.6/29.1

30/46

143.0/94.0

380

2.15

8.2

1.9

94

149

300

490

88

95

144

148

Single Core 21/35KV (Um=42KV) Dimensional Data


 Nom. Cross-Section Area


Unarmoured Cables

Aluminium Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

Cu

Al

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

50

9.3

0.1

16

2.0

35.7

1526

1239

1.2

2.0

2.3

43.5

2331

2116

70

9.3

0.1

16

2.1

37.6

1809

1393

1.2

2.5

2.4

46.6

2680

2325

95

9.3

0.1

16

2.2

39.4

2123

1555

1.2

2.5

2.5

48.4

2981

2482

120

9.3

0.1

16

2.2

40.8

2405

1688

1.4

2.5

2.5

49.8

3487

2867

150

9.3

0.1

25

2.2

42.3

2733

1838

1.4

2.5

2.6

51.5

3870

3055

185

9.3

0.1

25

2.3

44.7

3216

2082

1.4

2.5

2.6

53.5

4420

3370

240

9.3

0.1

25

2.4

46.9

3766

2333

1.4

2.5

2.7

55.8

4981

3676

300

9.3

0.1

25

2.4

49.3

4408

2605

1.4

2.5

2.8

58.5

5661

3971

400

9.3

0.1

35

2.5

52.3

5473

3057

1.6

2.5

2.9

61.7

6865

4550

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A CResistance CU / AL

ShortCircuit Ratingof Conductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Rating of Copper Wire Screen1 sec

Short Circuit Rating of Copper Tape Screen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat Spaced

Trefoil

Flat Spaced

Trefoil

Flat spaced

Cu

Al

Cu

Al

mm2

μΩ/m

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/ m

μΩ/ m

50

387/641

494/822

6.8/4.4

130

0.89

2.6

1.1

156

220

495

700

511

834

527

844

70

268/443

343/568

9.8/6.3

144

0.98

2.6

1.1

150

204

475

650

364

583

386

597

95

193/320

248/410

13.3/8.5

159

1.06

2.6

1.2

142

198

455

630

272

427

300

446

120

153/253

196/325

17.2/11.0

171

1.18

2.6

1.2

137

191

435

610

225

345

257

367

150

124/206

159/265

21.2/13.5

180

1.26

4.3

1.3

131

185

415

590

193

287

229

313

185

99.1/164

128/211

26.6/17.0

193

1.34

4.3

1.3

125

185

400

590

165

237

206

267

240

75.4/125

98/161

34.9/22.3

210

1.45

4.3

1.4

123

179

390

570

140

191

185

226

300

60.1/100

80/130

43.8/28.0

228

1.57

4.3

1.5

116

176

370

560

126

163

174

203

400

47.0/77.8

64/102

57.3/36.6

249

1.74

5.8

1.6

110

166

350

530

113

141

164

184

Single Core 26/35KV (Um=42KV) Dimensional Data


 Nom. Cross-Section Area


Unarmoured Cables

Aluminium Wire Armoured Cables

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Nom. Bedding Thickness

Armour Wire Size

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

Cu

Al

mm2

mm

mm

mm2

mm

mm

kg/km

mm

mm

mm

mm

kg/km

50

10.5

0.1

16

2.1

38.3

1689

1402

1.2

2.5

2.5

46.8

2580

2395

70

10.5

0.1

16

2.2

40.2

1980

1564

1.2

2.5

2.5

48.8

2937

2611

95

10.5

0.1

16

2.2

41.8

2283

1714

1.2

2.5

2.6

50.9

3206

2737

120

10.5

0.1

16

2.3

43.4

2588

1871

1.4

2.5

2.6

51.5

3753

3177

150

10.5

0.1

25

2.3

44.9

2923

2028

1.4

2.5

2.7

53.8

4143

3371

185

10.5

0.1

25

2.4

47.3

3415

2281

1.4

2.5

2.7

55.6

4694

3693

240

10.5

0.1

25

2.5

49.5

3975

2542

1.4

2.5

2.8

57.6

5258

4005

300

10.5

0.1

25

2.5

51.9

4625

2822

1.4

2.5

2.9

60.8

5940

4301

400

10.5

0.1

35

2.6

54.9

5704

3288

1.6

2.5

3.0

63.6

7155

4894

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross-Section Area

D C Resistance CU / AL

A CResistance CU / AL

ShortCircuit Ratingof Conductor CU / AL1 sec

Capaci-tance

Charging Current

Short Circuit Rating of Copper Wire Screen1 sec

Short Circuit Rating of Copper Tape Screen1 sec

Reactance

Inductance

Impedance

Trefoil

Flat Spaced

Trefoil

Flat Spaced

Trefoil

Flat spaced

Cu

Al

Cu

Al

mm2

μΩ/m

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

μΩ/ m

μΩ/ m

50

387/641

494/822

6.8/4.4

126

0.95

2.6

1.2

161

227

510

720

511

834

527

844

70

268/443

343/568

9.8/6.3

138

1.04

2.6

1.2

154

207

490

660

364

583

386

597

95

193/320

248/410

13.3/8.5

151

1.13

2.6

1.3

147

202

470

640

272

427

300

446

120

153/253

196/325

17.2/11.0

161

1.24

2.6

1.3

142

194

450

620

225

345

257

367

150

124/206

159/265

21.2/13.5

169

1.36

4.3

1.4

136

188

430

600

193

287

229

313

185

99.1/164

128/211

26.6/17.0

176

1.40

4.3

1.4

128

188

410

600

165

237

206

267

240

75.4/125

98/161

34.9/22.3

192

1.51

4.3

1.5

128

183

400

580

140

191

185

226

300

60.1/100

80/130

43.8/28.0

209

1.64

4.3

1.6

119

180

380

570

126

163

174

203

400

47.0/77.8

64/102

57.3/36.6

227

1.80

5.8

1.7

114

170

360

540

113

141

164

184

Current Rating for Single Core 1.8/3KV(Um=3.6KV ) to 26/35KV(Um=42KV) XLPE Insulation


 Nom. Cross-Section Area

Buried direct in Ground

Laid in Single Way Duct

Laid in Air

Trefoil

Flat spaced

Trefoil

Flat Touching

Trefoil

Flat Touching

Flat spaced

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

mm2

A

A

A

A

A

A

A

10

84

59

87

62

78

55

98

56

103

75

106

77

122

88

16

109

84

113

88

103

80

104

81

125

97

128

99

150

116

25

140

108

144

112

132

102

133

103

163

127

167

130

196

153

35

166

129

172

134

157

122

159

123

198

154

203

157

238

185

50

196

152

203

157

186

144

188

146

238

184

243

189

286

222

70

239

186

246

192

227

176

229

178

296

230

303

236

356

278

95

285

221

293

229

271

210

274

213

361

280

369

287

434

338

120

323

252

332

260

308

240

311

242

417

324

426

332

500

391

150

361

281

366

288

343

267

347

271

473

368

481

376

559

440

185

406

317

410

324

387

303

391

307

543

424

550

432

637

504

240

469

367

470

373

447

351

453

356

641

502

647

511

745

593

300

526

414

524

419

504

397

510

402

735

577

739

586

846

677

400

590

470

572

466

564

451

571

457

845

673

837

676

938

769

500

650

530

672

546

604

504

661

537

935

773

938

776

1118

919

630

700

600

882

646

654

554

771

617

1045

883

1048

886

1318

1089

800

750

660

1002

756

694

594

871

717

1145

983

1148

986

1528

1279

1000

800

720

1112

856

724

644

971

807

1235

1083

1238

1086

1738

1469

Current Rating for Single Core 1.8/3KV(Um=3.6KV) to 26/35KV(Um=42KV) EPR Insulation


 Nom. Cross-Section Area

Buried direct in Ground

Laid in Single Way Duct

Laid in Air

Trefoil

Flat spaced

Trefoil

Flat Touching

Trefoil

Flat Touching

Flat spaced

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

mm2

A

A

A

A

A

A

A

10

81

57

83

58

74

52

94

53

94

68

97

70

110

79

16

106

82

109

84

99

77

100

78

116

90

119

92

138

107

25

136

105

140

109

128

99

129

100

153

119

156

121

181

141

35

162

126

167

130

153

118

154

120

186

144

190

147

221

171

50

192

149

198

153

181

140

183

142

224

174

229

178

266

207

70

234

182

242

188

222

172

224

174

280

218

287

223

334

259

95

280

217

289

224

266

206

269

208

343

266

352

273

409

317

120

319

247

329

256

303

235

306

238

398

309

407

317

474

368

150

357

277

369

287

341

264

344

267

454

352

465

361

540

419

185

403

314

417

325

386

300

390

303

522

406

534

417

621

484

240

467

364

484

377

449

350

454

354

619

483

634

495

736

575

300

526

411

545

426

509

397

515

401

712

556

728

570

843

659

400

597

471

618

487

580

456

588

462

825

651

843

667

977

770

500

657

531

718

567

620

509

678

542

915

751

849

767

1157

920

630

707

601

928

667

670

559

788

622

1025

862

1054

876

1357

1090

800

757

661

1048

777

710

599

888

722

1125

961

1154

977

1567

1280

1000

807

721

1158

877

740

649

988

812

1215

1061

1244

1077

1777

1470

Current Rating Conditions:
 Ground Temperature: 20°CAmbient Temperature (air): 30°CDepth of Soil: 0.8mThermal Resistance of Soil: 1.5K•m/W