Three Core Cables To VDE 0276

Three Core Cables To VDE 0276

Supplying you with customized three core cables to vde 0276, it is one of the reliable three core cables to vde 0276 manufacturers and suppliers, welcome to wholesale our products at good price from our factory. Three Core Medium Power Cable to VDE 0276 Table 1. Insulation Thickness Insulation...

Product Details

Supplying you with customized three core cables to vde 0276, it is one of the reliable three core cables to vde 0276 manufacturers and suppliers, welcome to wholesale our products at good price from our factory.

Three Core Medium Power Cable to VDE 0276

Application:

The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

Standards:

DIN VDE 0276 Part 620 -622
HD 620 S1

Conductor:

Stranded compacted circular copper or aluminium conductors according to IEC
60228 class 2 / VDE 0276 class 2 / VDE 0295 HD 383. All internal interstices of the conductor are filled with water blocking compound to prevent ingress of water through conductor during storage, handing, installation and operation of the cable.

Conductor Screen:

The conductor screen consists of an extruded layer of non metallic, semi-conducting compound firmly bonded to the insulation to exclude all air voids. The screen has a minimum thickness of 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C.

Insulation:

Insulation is of extruded XLPE compound type 2XI1 according to DIN VDE 0207 part 22 and HD 620.1 with high degree of cross-linking, free from contaminants, air voids and heat resistant by dry cured process.
The nominal insulation wall thickness is shown in table 1.

Table 1.Insulation Thickness


 Nom. Cross-Section Area

Insulation Thickness at Nom. Voltage

3.6/6kV (Um=7.2)kV

6/10KV (Um=12KV)

8.7/15KV (Um=17KV)

12/20KV (Um=24KV)

18/30KV (Um=36KV)

mm2

mm

mm

mm

mm

mm


XLPE

XLPE

XLPE

XLPE

XLPE

35

2.5

3.4

4.5

5.5

-

50

2.5

3.4

4.5

5.5

8.0

70

2.5

3.4

4.5

5.5

8.0

95

2.5

3.4

4.5

5.5

8.0

120

2.5

3.4

4.5

5.5

8.0

150

2.5

3.4

4.5

5.5

8.0

185

2.5

3.4

4.5

5.5

8.0

240

2.6

3.4

4.5

5.5

8.0

300

2.8

3.4

4.5

5.5

8.0

400

3.0

3.4

4.5

5.5

8.0

Insulation Screen: The insulation screen consists of extruded non metallic, semi-conducting compound extruded over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. The minimum thickness is 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site.
Conducting Water Blocking Layer: The insulation screen may be covered by semi- conductive water blocking tape which will swell up under the influence of moisture of water to ensure longitudinal watertightness.
Metallic Screen: Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with minimum thickness of 0.1mm is applied helically with overlap. Total cross section of metallic screen layer is shown in table 2. The screen can withstand of fault current to earth of 1000 A for one second at maximum temperature of 160°C. Minimum cross section of concentric conductor is according to DIN VDE 0273 & 0276 as shown.
Table 2. Minimum Total Cross Section of Metallic Screen

Nominal Cross-Section Area Of Cable

Minimum Cross-Section of Metallic Screen

DC Resistance of the Copper Wire Screen

mm²

mm²

mm

Up to 120

16

1.06

150-300

25

0.72

400-630

35

0.51

800-1000

50

0.35

Separator / Water Blocking Layer:The metallic screen may be covered by non-conducting water blocking tape which will swell up under the influence of moisture of water to ensure longitudinal watertightness.
Separation Sheath (for armoured cable):The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour. Thickness of separation sheath is shown in table 3.
Table 3. Separation Sheath Thickness

Cores Diameter

Approx.Thickess of Inner Sheath

mm

mm

>

<< p="">


35

45

1.4

45

60

1.6

60

80

1.8

80

-

2.0

Armour(for armoured cable): The armour consists of:
1) Double layers of galvanized steel tape are applied helically with proper inner overlapping over an extruded separation sheath. Thickness of the steel tape is shown in table 4.
Tabel 4. Galvanized Steel Tape Thickness

Inner Diameter

Thickness of Galvanized Steel Tape

mm

mm

>

<< p="">


-

30

0.2

30

70

0.5

70

-

0.8

2) Galvanized flat steel wires with thickness of 0.8 mm are applied helically over the surface of inner sheath with minimum of 90% coverage. And galvanized Steel tape with nominal thickness of 0.3 mm is applied helically with 50% coverage to cover the surface of the flat wires.
Outer Sheath:Overall sheath comprises a layer of extruded PE compound DMP2 according to HD620.1 and 2YM3 type to DIN VDE 0276 Part 3, or PVC compound DMV6 according to HD620.1 and YM5 to DIN VDE 0276 Part 6. Normal wall thickness is 2.5mm (1/500mm 18/30sq 2.6mm), suitable for exposure to sun-light or other local atmospheric environments and for the operating temperature of the cable.
PHYSICAL PROPERTIES:
Operating Temperature: up to 90°C
Temperature Range: -5°C ( PVC sheath ); -20°C ( PE sheath )
Short Circuit Temperature: 250°C (short circuit duration up to 5 seconds)
Bending Radius: 15 x OD (Cable without metal sheath)
30 x OD (Cable with aluminium sheath)
Table 5. Nominal /Operating /Testing Voltages

Nominal Voltage Uo/U

Operating Voltage (Um)

Testing Voltage

3.6/6KV

8KV

12.5KV

6/10KV

12KV

21KV

8.7/15KV

18KV

30.5KV

12/20KV

24KV

42KV

18/30KV

36KV

63KV

Medium Voltage Cables to VDE 0276
TYPE CODES:
Conductor
N According to VDE Standard (No abbreviation for copper conductor) A Aluminium conductor
Copper conductor
Insulation
2X XLPE
Screen
CConcentric conductor of copper
CE Concentric conductor of copper over each individual core
SScreen of copper wires & copper tape,helically wound
SE Screen of copper wires over each individual cores
(G) Longitudinally waterproof
Armour
F Armour of galvanized flat steel wire
G Counter Helix of galvanized steel tape
B Steel tape armouring
R Armour of galvanized round steel wire
Sheath
2Y PE
Y PVC H LSZH
K Lead sheath
KL Aluminium sheath
Three Core 3.6/6KV (Um=7.2KV)
N2XSEY
NA2XSEY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

Mm2

mm

mm

mm

mm2

mm

mm

mm

kg / km

kg / km

25

6.05

2.5

0.1

16

12.5

1.5

37

2100

1600

35

7.10

2.5

0.1

16

13.5

1.6

39

2500

1800

50

8.25

2.5

0.1

16

14.7

1.6

42

3000

2100

70

9.90

2.5

0.1

16

16.3

1.7

46

3800

2500

95

11.7

2.5

0.1

16

18.1

1.7

50

4800

3000

120

13.1

2.5

0.1

16

19.5

1.8

53

5800

3500

150

14.3

2.5

0.1

25

20.7

1.8

56

6700

3900

185

16.3

2.5

0.1

25

22.7

1.9

60

8100

4600

240

18.7

2.6

0.1

25

25.3

1.9

66

10200

5600

300

20.9

2.8

0.1

25

27.9

2.0

72

12500

6700

400

23.7

3.0

0.1

35

31.1

2.1

80

15600

8200

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 3.6/6KV (Um=7.2KV) Galvanized Steel Tape Armoured Cables
N2XSEYBY NA2XSEYBY Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm²

mm

mm

mm

mm²

mm

mm

mm

mm

kg / km

kg / km

25

6.05

2.5

0.1

16

12.5

0.5

2.2

39

2800

2300

35

7.10

2.5

0.1

16

13.5

0.5

2.3

42

3200

2600

50

8.25

2.5

0.1

16

14.7

0.5

2.4

45

3800

2900

70

9.90

2.5

0.1

16

16.3

0.5

2.5

49

4700

3400

95

11.7

2.5

0.1

16

18.1

0.5

2.6

53

5800

4000

120

13.1

2.5

0.1

16

19.5

0.5

2.7

56

6800

4600

150

14.3

2.5

0.1

25

20.7

0.5

2.8

59

7900

5100

185

16.3

2.5

0.1

25

22.7

0.8

2.9

64

9400

5900

240

18.7

2.6

0.1

25

25.3

0.8

3.1

70

11700

7000

300

20.9

2.8

0.1

25

27.9

0.8

3.3

76

14100

8300

400

23.7

3.0

0.1

35

31.1

0.8

3.6

85

18300

10900

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 3.6/6KV (Um=7.2KV) Galvanized Flat Steel wire+Steel Tape Armoured Cables
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm²

mm

mm

mm

mm²

mm

mm

mm

kg / km

kg / km

25

6.05

2.5

0.1

16

12.5

1.5

37

2100

1600

35

7.10

2.5

0.1

16

13.5

1.6

39

2500

1800

50

8.25

2.5

0.1

16

14.7

1.6

42

3000

2100

70

9.90

2.5

0.1

16

16.3

1.7

46

3800

2500

95

11.7

2.5

0.1

16

18.1

1.7

50

4800

3000

120

13.1

2.5

0.1

16

19.5

1.8

53

5800

3500

150

14.3

2.5

0.1

25

20.7

1.8

56

6700

3900

185

16.3

2.5

0.1

25

22.7

1.9

60

8100

4600

240

18.7

2.6

0.1

25

25.3

1.9

66

10200

5600

300

20.9

2.8

0.1

25

27.9

2.0

72

12500

6700

400

23.7

3.0

0.1

35

31.1

2.1

80

15600

8200

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 3.6/6KV (Um=7.2KV) Galvanized Steel Tape Armoured Cables
N2XSEYBY NA2XSEYBY Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

25

6.05

2.5

0.1

16

12.5

0.5

2.2

39

2800

2300

35

7.10

2.5

0.1

16

13.5

0.5

2.3

42

3200

2600

50

8.25

2.5

0.1

16

14.7

0.5

2.4

45

3800

2900

70

9.90

2.5

0.1

16

16.3

0.5

2.5

49

4700

3400

95

11.7

2.5

0.1

16

18.1

0.5

2.6

53

5800

4000

120

13.1

2.5

0.1

16

19.5

0.5

2.7

56

6800

4600

150

14.3

2.5

0.1

25

20.7

0.5

2.8

59

7900

5100

185

16.3

2.5

0.1

25

22.7

0.8

2.9

64

9400

5900

240

18.7

2.6

0.1

25

25.3

0.8

3.1

70

11700

7000

300

20.9

2.8

0.1

25

27.9

0.8

3.3

76

14100

8300

400

23.7

3.0

0.1

35

31.1

0.8

3.6

85

18300

10900

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 3.6/6KV (Um=7.2KV) Galvanized Flat Steel wire+Steel Tape Armoured Cables
N2XSEYFGbY
NA2XSEYFGbY Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

25

6.05

2.5

0.1

16

12.5

0.8

2.2

40

2900

2400

35

7.10

2.5

0.1

16

13.7

0.8

2.3

42

3300

2700

50

8.25

2.5

0.1

16

14.7

0.8

2.4

45

3900

3000

70

9.90

2.5

0.1

16

16.3

0.8

2.5

49

4900

3600

95

11.7

2.5

0.1

16

18.1

0.8

2.6

53

6000

4200

120

13.1

2.5

0.1

16

19.5

0.8

2.7

56

7000

4700

150

14.3

2.5

0.1

25

20.7

0.8

2.8

59

8100

5200

185

16.3

2.5

0.1

25

22.7

0.8

2.9

64

9600

6100

240

18.7

2.6

0.1

25

25.3

0.8

3.1

70

11900

7200

300

20.9

2.8

0.1

25

27.9

0.8

3.3

76

14300

8600

400

23.7

3.0

0.1

35

31.1

0.8

3.6

84

17700

10300

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross- Section Area

D C Resistance CU / AL

A C Resistance CU / AL

Short Circuit Rating of Conductor CU / AL 1 sec

Capacitance

Charging Current

Short Circuit Rating of Copper Wire Screen Per Core 1 sec

Short Circuit Rating of Copper Tape Screen Per Core 1 sec

Reactance

Inductance

mm2

μΩ/m

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

25

727/1200

927/1538

3.6/2.3

272

0.33

2.6

0.4

116

370

35

524/868

668/1113

5.0/3.2

301

0.36

2.6

0.5

108

350

50

387/641

494/822

6.8/4.4

332

0.40

2.6

0.5

102

330

70

268/443

343/568

9.8/6.3

383

0.46

2.6

0.6

97

310

95

193/320

248/410

13.3/8.5

432

0.52

2.6

0.6

92

290

120

153/253

196/325

17.2/11.0

474

0.57

2.6

0.7

89

280

150

124/206

159/265

21.2/13.5

511

0.61

4.3

0.7

87

280

185

99.1/164

128/211

26.6/17.0

562

0.67

4.3

0.8

86

270

240

75.4/125

98/161

34.9/22.3

602

0.72

4.3

0.9

83

260

300

60.1/100

80/130

43.8/28.0

622

0.75

4.3

1.0

82

260

400

47.0/77.8

64/102

57.3/36.6

648

0.78

5.8

1.1

80

250

Three Core 6/10KV (Um=12KV)
N2XSEY
NA2XSEY Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

kg / km

kg / km

25

6.05

3.4

0.1

16

14.3

1.6

41

2400

1900

35

7.10

3.4

0.1

16

15.3

1.6

43

2800

2200

50

8.25

3.4

0.1

16

16.5

1.7

46

3400

2500

70

9.90

3.4

0.1

16

18.1

1.7

50

4200

2900

95

11.7

3.4

0.1

16

19.9

1.8

54

5300

3400

120

13.1

3.4

0.1

16

21.3

1.8

57

6200

3900

150

14.3

3.4

0.1

25

22.5

1.9

60

7200

4400

185

16.3

3.4

0.1

25

24.5

1.9

64

8600

5100

240

18.7

3.4

0.1

25

26.9

2.0

70

10700

6100

300

20.9

3.4

0.1

25

29.1

2.1

75

12900

7100

400

23.7

3.4

0.1

35

31.9

2.2

81

15900

8500

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 6/10KV (Um=12KV) Galvanized Steel Tape Armoured Cables
N2XSEYBY
NA2XSEYBY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg/km

kg/km

25

6.05

3.4

0.1

16

14.3

0.5

2.3

44

3200

2700

35

7.10

3.4

0.1

16

15.3

0.5

2.4

46

3700

3000

50

8.25

3.4

0.1

16

16.5

0.5

2.5

49

4300

3400

70

9.90

3.4

0.1

16

18.1

0.5

2.6

53

5200

3900

95

11.7

3.4

0.1

16

19.9

0.5

2.8

57

6400

4600

120

13.1

3.4

0.1

16

21.3

0.5

2.9

61

7400

5200

150

14.3

3.4

0.1

25

22.5

0.5

3.0

64

8500

5700

185

16.3

3.4

0.1

25

24.5

0.5

3.1

68

10000

6500

240

18.7

3.4

0.1

25

26.9

0.5

3.3

74

12300

7600

300

20.9

3.4

0.1

25

29.1

0.5

3.4

79

14600

8800

400

23.7

3.4

0.1

35

31.9

0.8

3.7

87

18700

11300

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 6/10KV (Um=12KV) Galvanized Flat Steel wire Armoured Cables
N2XSEYFGbY
NA2XSEYFGbY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

25

6.05

3.4

0.1

16

14.3

0.8

2.3

44

3300

2800

35

7.10

3.4

0.1

16

15.3

0.8

2.4

46

3800

3100

50

8.25

3.4

0.1

16

16.5

0.8

2.5

49

4400

3500

70

9.90

3.4

0.1

16

18.1

0.8

2.6

53

5400

4100

95

11.7

3.4

0.1

16

19.9

0.8

2.8

57

6500

4700

120

13.1

3.4

0.1

16

21.3

0.8

2.9

61

7600

5300

150

14.3

3.4

0.1

25

22.5

0.8

3.0

64

8700

5900

185

16.3

3.4

0.1

25

24.5

0.8

3.1

68

10200

6800

240

18.7

3.4

0.1

25

26.9

0.8

3.3

74

12500

7900

300

20.9

3.4

0.1

25

29.1

0.8

3.4

79

14900

9100

400

23.7

3.4

0.1

35

31.9

0.8

3.7

86

18000

10600

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross- Section Area

D C Resistance CU / AL

A C Resistance CU / AL

Short Circuit Rating of Conductor CU / AL 1 sec

Capacitance

Charging Current

Short Circuit Rating of Copper Wire Screen Per Core 1 sec

Short Circuit Rating of Copper Wire Screen Per Core 1 sec

Reactance

Inductance

mm2

μΩ/m

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

25

727/1200

927/1538

3.6/2.3

204

0.43

2.6

0.5

129

405

35

524/868

668/1113

5.0/3.2

237

0.47

2.6

0.6

115

370

50

387/641

494/822

6.8/4.4

260

0.52

2.6

0.6

109

350

70

268/443

343/568

9.8/6.3

298

0.60

2.6

0.7

103

330

95

193/320

248/410

13.3/8.5

334

0.67

2.6

0.7

99

320

120

153/253

196/325

17.2/11.0

365

0.73

2.6

0.8

96

310

150

124/206

159/265

21.2/13.5

392

0.78

4.3

0.8

93

300

185

99.1/164

128/211

26.6/17.0

430

0.86

4.3

0.9

90

290

240

75.4/125

98/161

34.9/22.3

476

0.95

4.3

0.9

87

280

300

60.1/100

80/130

43.8/28.0

524

1.05

4.3

1.0

85

270

400

47.0/77.8

64/102

57.3/36.6

580

1.16

5.8

1.1

81

260

Three Core 8.7/15KV (Um=17.5KV)
N2XSEY
NA2XSEY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

kg / km

kg / km

25

6.05

4.5

0.1

16

16.5

1.7

46

3500

2400

35

7.10

4.5

0.1

16

17.5

1.7

48

3800

2600

50

8.25

4.5

0.1

16

18.7

1.7

51

4400

3000

70

9.90

4.5

0.1

16

20.3

1.8

55

5300

3400

95

11.7

4.5

0.1

16

22.1

1.8

59

6400

4000

120

13.1

4.5

0.1

16

23.5

1.9

62

7400

4500

150

14.3

4.5

0.1

25

24.7

1.9

65

8500

5000

185

16.3

4.5

0.1

25

26.7

2.0

69

10000

5800

240

18.7

4.5

0.1

25

29.1

2.1

75

12200

6800

300

20.9

4.5

0.1

25

31.3

2.1

80

14400

7900

400

23.7

4.5

0.1

35

34.1

2.2

87

17500

9300

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 8.7/15KV (Um=17.5KV) Galvanized Steel Tape Armoured Cables
N2XSEYBY
NA2XSEYBY
Dimensional Data

Nom. Cross- Section Area

Approx Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

25

6.05

4.5

0.1

16

16.5

0.5

2.5

49

3800

3300

35

7.10

4.5

0.1

16

17.5

0.5

2.6

51

4300

3600

50

8.25

4.5

0.1

16

18.7

0.5

2.7

54

4900

4000

70

9.90

4.5

0.1

16

20.3

0.5

2.8

58

5900

4600

95

11.7

4.5

0.1

16

22.1

0.5

2.9

62

7100

5300

120

13.1

4.5

0.1

16

23.5

0.5

3.0

66

8100

5900

150

14.3

4.5

0.1

25

24.7

0.5

3.1

69

9200

6400

185

16.3

4.5

0.1

25

26.7

0.5

3.3

74

10900

7400

240

18.7

4.5

0.1

25

29.1

0.5

3.4

79

13100

8500

300

20.9

4.5

0.1

25

31.3

0.5

3.6

86

16400

10600

400

23.7

4.5

0.1

35

34.1

0.8

3.9

93

19700

12300

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 8.7/15KV (Um=17.5KV) Galvanized Flat Steel Wire Armoured Cables
N2XSEYFGbY
NA2XSEYFGbY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

25

6.05

4.5

0.1

16

16.5

0.8

2.5

49

3400

3400

35

7.10

4.5

0.1

16

17.5

0.8

2.6

51

4400

3800

50

8.25

4.5

0.1

16

18.7

0.8

2.7

54

5100

4200

70

9.90

4.5

0.1

16

20.3

0.8

2.8

58

6000

4700

95

11.7

4.5

0.1

16

22.1

0.8

2.9

62

7300

5400

120

13.1

4.5

0.1

16

23.5

0.8

3.0

66

8300

6100

150

14.3

4.5

0.1

25

24.7

0.8

3.1

69

9400

6600

185

16.3

4.5

0.1

25

26.7

0.8

3.3

74

11100

7600

240

18.7

4.5

0.1

25

29.1

0.8

3.4

79

13400

8700

300

20.9

4.5

0.1

25

31.3

0.8

3.6

85

15800

10000

400

23.7

4.5

0.1

35

34.1

0.8

3.9

91

19000

11600

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

 Nom. Cross- Section Area

 D C Resistance CU / AL

A C Resistance CU / AL

 Short Circuit Rating of Conductor CU / AL 1 sec

Capacitance

 Charging Current

Short Circuit Rating of Copper Wire Screen Per Core 1 sec

Short Circuit Rating of Copper Tape Screen Per Core 1 sec

Reactance

Inductance

mm2

μΩm

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩm

nH/m

25

727/1200

927/1538

3.6/2.3

176

0.48

2.6

0.6

132

410

35

524/868

668/1113

5.0/3.2

193

0.53

2.6

0.6

123

390

50

387/641

494/822

6.8/4.4

211

0.58

2.6

0.7

116

370

70

268/443

343/568

9.8/6.3

240

0.65

2.6

0.7

110

350

95

193/320

248/410

13.3/8.5

267

0.73

2.6

0.8

105

330

120

153/253

196/325

17.2/11.0

291

0.79

2.6

0.8

102

320

150

124/206

159/265

21.2/13.5

312

0.85

4.3

0.9

98

310

185

99.1/164

128/211

26.6/17.0

340

0.93

4.3

0.9

95

300

240

75.4/125

98/161

34.9/22.3

375

1.02

4.3

1.0

91

290

300

60.1/100

80/130

43.8/28.0

411

1.12

4.3

1.1

89

280

400

47.0/77.8

64/102

57.3/36.6

454

1.24

5.8

1.2

84

270

Three Core 12/20KV (Um=24KV)
N2XSEY
NA2XSEY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

kg / km

kg / km

35

7.10

5.5

0.1

16

19.7

1.8

53

3800

3100

50

8.25

5.5

0.1

16

20.9

1.8

56

4400

3500

70

9.90

5.5

0.1

16

22.5

1.9

60

5300

4000

95

11.7

5.5

0.1

16

24.3

1.9

64

6400

4600

120

13.1

5.5

0.1

16

25.7

2.0

67

7400

5200

150

14.3

5.5

0.1

25

26.9

2.0

70

8500

5700

185

16.3

5.5

0.1

25

28.9

2.1

75

10000

6500

240

18.7

5.5

0.1

25

31.3

2.1

80

12200

7500

300

20.9

5.5

0.1

25

33.5

2.2

85

14400

8700

400

23.7

5.5

0.1

35

36.3

2.3

91

17500

10200

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 12/20KV (Um=24KV) Galvanized Steel Tape Armoured Cables
N2XSEYBY NA2XSEYBY Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom.
 Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

35

7.10

5.5

0.1

16

19.7

0.5

2.7

57

4900

4200

50

8.25

5.5

0.1

16

20.9

0.5

2.9

60

5600

4700

70

9.90

5.5

0.1

16

22.5

0.5

3.0

64

6600

5300

95

11.7

5.5

0.1

16

24.3

0.5

3.1

68

7800

6000

120

13.1

5.5

0.1

16

25.7

0.5

3.2

71

8900

6600

150

14.3

5.5

0.1

25

26.9

0.5

3.3

74

10100

7200

185

16.3

5.5

0.1

25

28.9

0.5

3.4

79

11700

8200

240

18.7

5.5

0.1

25

31.3

0.8

3.6

86

14900

10200

300

20.9

5.5

0.1

25

33.5

0.8

3.8

91

17400

11600

400

23.7

5.5

0.1

35

36.3

0.8

4.0

98

20800

13400

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 12/20KV (Um=24KV) Galvanized Flat Steel Wire Armoured Cables
N2XSEYFGbY NA2XSEYFGbY Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

Mm2

mm

mm

mm

mm

kg / km

kg / km

35

7.10

5.5

0.1

16

19.7

0.8

2.7

57

5000

4400

50

8.25

5.5

0.1

16

20.9

0.8

2.9

60

5700

4800

70

9.90

5.5

0.1

16

22.5

0.8

3.0

64

6800

5400

95

11.7

5.5

0.1

16

24.3

0.8

3.1

68

8000

6200

120

13.1

5.5

0.1

16

25.7

0.8

3.2

71

9100

6800

150

14.3

5.5

0.1

25

26.9

0.8

3.3

74

10300

7500

185

16.3

5.5

0.1

25

28.9

0.8

3.4

79

11900

8400

240

18.7

5.5

0.1

25

31.3

0.8

3.6

85

14300

9600

300

20.9

5.5

0.1

25

33.5

0.8

3.8

90

16700

10900

400

23.7

5.5

0.1

35

36.3

0.8

4.0

97

20100

12700

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

 Nom. Cross- Section Area

D C Resistance CU / AL

 A C Resistance CU / AL

 Short Circuit Rating of Conductor CU / AL 1 sec

Capaci- tance

 Charging Current

Short Circuit Rating of Copper Wire Screen Per Core 1 sec

Short Circuit Rating of Copper Tape Screen Per Core 1 sec

 Reactance

 Inductance

mm2

μΩ/m

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

35

524/868

668/1113

5.0/3.2

168

0.67

2.6

0.7

129

410

50

387/641

494/822

6.8/4.4

183

0.73

2.6

0.8

122

390

70

268/443

343/568

9.8/6.3

207

0.83

2.6

0.8

115

370

95

193/320

248/410

13.3/8.5

229

0.92

2.6

0.9

110

350

120

153/253

196/325

17.2/11.0

249

1.00

2.6

0.9

106

340

150

124/206

159/265

21.2/13.5

266

1.06

4.3

1.0

103

330

185

99.1/164

128/211

26.6/17.0

289

1.16

4.3

1.0

100

320

240

75.4/125

98/161

34.9/22.3

318

1.27

4.3

1.1

95

300

300

60.1/100

80/130

43.8/28.0

348

1.39

4.3

1.2

93

300

400

47.0/77.8

64/102

57.3/36.6

388

1.53

5.8

1.3

87

280

Three Core 18/30KV (Um=36KV)
N2XSEY
NA2XSEY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

kg / km

kg / km

50

8.25

8.0

0.1

16

25.9

2.0

68

5800

4900

70

9.90

8.0

0.1

16

27.5

2.0

71

6800

5500

95

11.7

8.0

0.1

16

29.3

2.1

75

8000

6100

120

13.1

8.0

0.1

16

30.7

2.1

79

9000

6700

150

14.3

8.0

0.1

25

31.9

2.2

81

10100

7300

185

16.3

8.0

0.1

25

33.9

2.2

86

11800

8300

240

18.7

8.0

0.1

25

36.3

2.3

91

14000

9400

300

20.9

8.0

0.1

25

38.5

2.4

97

16500

10700

400

23.7

8.0

0.1

35

41.3

2.5

103

19700

12300

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard
Three Core 18/30KV (Um=36KV) Galvanized Steel Tape Armoured Cables
N2XSEYBY
NA2XSEYBY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

50

8.25

8.0

0.1

16

25.9

0.5

3.2

72

7300

6400

70

9.90

8.0

0.1

16

27.5

0.5

3.3

75

8400

7100

95

11.7

8.0

0.1

16

29.3

0.5

3.5

80

9700

7900

120

13.1

8.0

0.1

16

30.7

0.8

3.6

84

11700

9400

150

14.3

8.0

0.1

25

31.9

0.8

3.7

87

12900

10100

185

16.3

8.0

0.1

25

33.9

0.8

3.9

92

14800

11300

240

18.7

8.0

0.1

25

36.3

0.8

4.0

98

17300

12600

300

20.9

8.0

0.1

25

38.5

0.8

4.2

103

20000

14100

400

23.7

8.0

0.1

35

41.3

0.8

4.4

110

23500

16000

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Three Core 18/30KV (Um=36KV) Galvanized Flat Steel wire Armoured Cables
N2XSEYFGbY
NA2XSEYFGbY
Dimensional Data

Nom. Cross- Section Area

Approx. Conductor Diameter

Nom. Insulation Thickness

Copper Tape Thickness

Copper Wire Screen Area*

Approx. Insulation Diameter

Nom. Armour Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

Cu

Al

mm2

mm

mm

mm

mm2

mm

mm

mm

mm

kg / km

kg / km

50

8.25

8.0

0.1

16

25.9

0.8

3.2

72

7500

6600

70

9.90

8.0

0.1

16

27.5

0.8

3.3

76

8600

7300

95

11.7

8.0

0.1

16

29.3

0.8

3.5

80

10000

8100

120

13.1

8.0

0.1

16

30.7

0.8

3.6

83

11200

8900

150

14.3

8.0

0.1

25

31.9

0.8

3.7

86

12400

9500

185

16.3

8.0

0.1

25

33.9

0.8

3.9

91

14100

10600

240

18.7

8.0

0.1

25

36.3

0.8

4.0

97

16600

11900

300

20.9

8.0

0.1

25

38.5

0.8

4.2

102

19200

13400

400

23.7

8.0

0.1

35

41.3

0.8

4.4

109

22700

15300

*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Electrical Data

Nom. Cross- Section Area

D C Resistance CU / AL

A C Resistance CU / AL

Short Circuit Rating of Conductor CU / AL 1 sec

Capacitance

Charging Current

Short Circuit Rating of Copper Wire Screen Per Core 1 sec

Short Circuit Rating of Copper Tape Screen Per Core 1 sec

Reactance

Inductance

mm2

μΩ/m

μΩ/m

kA

pF/m

mA/m

kA

kA

μΩ/m

nH/m

50

387/641

494/822

6.8/4.4

142

0.85

2.6

1.0

134

430

70

268/443

343/568

9.8/6.3

159

0.95

2.6

1.0

127

400

95

193/320

248/410

13.3/8.5

175

1.05

2.6

1.1

121

390

120

153/253

196/325

17.2/11.0

189

1.13

2.6

1.1

117

370

150

124/206

159/265

21.2/13.5

201

1.21

4.3

1.2

113

360

185

99.1/164

128/211

26.6/17.0

217

1.3

4.3

1.2

109

350

240

75.4/125

98/161

34.9/22.3

237

1.42

4.3

1.3

104

330

300

60.1/100

80/130

43.8/28.0

258

1.55

4.3

1.4

101

320

400

47.0/77.8

64/102

57.3/36.6

282

1.69

5.8

1.5

96

290

Current Rating for Three Core 1.8/3KV(Um=7.2KV ) to 26/35KV(Um=42KV) XLPE Insulation


Unarmored

Armored

Nom. Cross- Section Area

Buried direct in Ground

Laid in Single Way Duct

Laid in Air

Buried direct in Ground

Laid in Single Way Duct

Laid in Air

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

mm2

A

A

A

A

A

A

10

76

53

62

42

87

62

76

53

63

43

88

63

16

101

78

87

67

109

84

101

78

88

68

110

85

25

129

100

112

87

142

110

129

100

112

87

143

111

35

153

119

133

103

170

132

154

119

134

104

172

133

50

181

140

158

122

204

158

181

140

158

123

205

159

70

221

171

193

150

253

196

220

171

194

150

253

196

95

262

203

231

179

304

236

263

204

232

180

307

238

120

298

232

264

205

351

273

298

232

264

206

352

274

150

334

260

297

231

398

309

332

259

296

231

397

309

185

377

294

336

262

455

355

374

293

335

262

453

354

240

434

340

390

305

531

415

431

338

387

304

529

415

300

489

384

441

346

606

475

482

380

435

343

599

472

400

553

438

501

398

696

552

541

432

492

393

683

545

500

613

498

541

451

786

652

601

492

532

446

773

645

630

663

568

591

501

896

762

651

562

582

496

883

755

Current Rating for Three Core 1.8/3KV(Um=7.2KV ) to 26/35KV(Um=42KV) XLPE Insulation


Unarmored

Armored

Nom. Cross- Section Area

Buried direct in Ground

Laid in Single Way Duct

Laid in Air

Buried direct in Ground

Laid in Single Way Duct

Laid in Air

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

CU

AL

mm2

A

A

A

A

A

A

10

76

53

62

42

87

62

76

53

63

43

88

63

16

101

78

87

67

109

84

101

78

88

68

110

85

25

129

100

112

87

142

110

129

100

112

87

143

111

35

153

119

133

103

170

132

154

119

134

104

172

133

50

181

140

158

122

204

158

181

140

158

123

205

159

70

221

171

193

150

253

196

220

171

194

150

253

196

95

262

203

231

179

304

236

263

204

232

180

307

238

120

298

232

264

205

351

273

298

232

264

206

352

274

150

334

260

297

231

398

309

332

259

296

231

397

309

185

377

294

336

262

455

355

374

293

335

262

453

354

240

434

340

390

305

531

415

431

338

387

304

529

415

300

489

384

441

346

606

475

482

380

435

343

599

472

400

553

438

501

398

696

552

541

432

492

393

683

545

500

613

498

541

451

786

652

601

492

532

446

773

645

630

663

568

591

501

896

762

651

562

582

496

883

755