Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables PVC Sheath

Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables PVC Sheath

Supplying you with customized flame retardant cat6 cwb/swb/swa armoured data cables pvc sheath, it is one of the reliable flame retardant cat6 cwb/swb/swa armoured data cables pvc sheath manufacturers and suppliers, welcome to wholesale our products at good price from our factory. Flame...

Product Details

Supplying you with customized flame retardant cat6 cwb/swb/swa armoured data cables pvc sheath, it is one of the reliable flame retardant cat6 cwb/swb/swa armoured data cables pvc sheath manufacturers and suppliers, welcome to wholesale our products at good price from our factory.

Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables

CAT6 U/UTP4P23
CAT6 F/UTP4P23
CAT6 SF/FTP4P23

Application:

Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.

STANDARDS:

Basic design adapted to EN50173

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)**

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

VOLTAGE RATING

60V

CABLE CONSTRUCTION

Conductors: 23AWG solid bare copper.

Insulation: HDPE.

Twinning: Two coloured insulated conductors twisted together to form a pair.

Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.

Armouring:

cwb: copper Wire Braid

swb: Steel Wire

Braid swa: Steel Wire Armour

Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

Cat6 F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.

Cat6 SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.

Physical AND THERMAL PROPERTIES

Temperature range: -30°C ~ +75°C

Minimum bending radius during installation (mobile state): 8 x Overall Diameter

Minimum bending radius during operation (fixed state): 4 x Overall Diameter

Electrical Properties

AWG


23

Nominal Conductor Diameter

mm

0.56/0.57/0.58

Maximum DC Resistant@20°C

Ω /100m

9.38

Maximum DCR Unbalance

%

3

Maximum Mutual Capacitance

pF/m

5.8

Maximum Capacitance Unbalance

pF/100m

30

Characteristic Impedance@1-100MHz

Ω

100+/-15

Maximum Propagation Delay Skew

ns/100m

18

Transmission Properties

FREQ MHz

Maximum Attenuation dB/100m

Minimum NEXT dB

Minimum PSNEXT dB

Minimum ELFEXT dB/100m

Minimum PSELFEXT dB/100m

Minimum RL dB

0.772

1.8

76.0

74.

70.0

67.0

1

2.0

74.3

72.3

67.8

64.8

20.0

4

3.8

65.3

63.3

55.7

52.7

23.0

8

5.3

60.8

58.8

49.7

46.7

24.5

10

6.0

59.3

57.3

47.8

44.8

25.0

16

7.6

56.3

54.3

43.7

40.7

25.0

20

8.5

54.8

52.8

41.7

38.7

25.0

25

9.5

53.3

51.3

39.8

36.8

24.3

31.25

10.7

51.9

49.9

37.9

34.9

23.6

62.5

15.4

47.4

45.4

31.8

28.8

21.5

100

19.8

44.3

42.3

27.8

24.8

20.1

155

25.2

41.5

39.5

23.9

20.9

18.8

200

29.0

39.8

37.8

21.7

18.7

18.0

250

32.8

38.3

36.3

19.8

16.8

17.3

Cat6 SF/UTP

CONSTRUCTION PARAMETERS

Cable Code

Construction No. of elements×No. of cores in element×Conductor diameter

Nominal Insulation Thickness

Nominal Inner Sheath Thickness

Nominal Outer Sheath Thickness

Nominal Overall Diameter

Nominal Weight


mm

mm

mm

mm

mm

kg/km

CAT6 U/UTP CWB

4×2×0.56/0.57

0.2

0.6

1.0

7.88

115

CAT6 U/UTP SWB

4×2×0.56/0.57

0.2

0.6

1.0

7.88

109

CAT6 U/UTP SWA

4×2×0.56/0.57

0.2

0.6

1.0

8.88

189

CAT6 F/UTP CWB

4×2×0.57/0.58

0.2

0.6

1.0

8.48

126

CAT6 F/UTP SWB

4×2×0.57/0.58

0.2

0.6

1.0

8.48

132

CAT6 F/UTP SWA

4×2×0.57/0.58

0.2

0.6

1.0

9.48

213

CAT6 SF/UTP CWB

4×2×0.57/0.58

0.2

0.6

1.0

8.96

154

CAT6 SF/UTP SWB

4×2×0.57/0.58

0.2

0.6

1.0

8.96

148

CAT6 SF/UTP SWA

4×2×0.57/0.58

0.2

0.6

1.0

9.96

242