600 1000V XLPE Insulated, PVC Sheathed, Double Steel Tape Armoured Power Cables (3 Cores)

600 1000V XLPE Insulated, PVC Sheathed, Double Steel Tape Armoured Power Cables (3 Cores)

Supplying you with customized 600 1000v xlpe insulated, pvc sheathed, double steel tape armoured power cables (3 cores), it is one of the reliable 600 1000v xlpe insulated, pvc sheathed, double steel tape armoured power cables (3 cores) manufacturers and suppliers, welcome to wholesale our...

Product Details

Supplying you with customized 600 1000v xlpe insulated, pvc sheathed, double steel tape armoured power cables (3 cores), it is one of the reliable 600 1000v xlpe insulated, pvc sheathed, double steel tape armoured power cables (3 cores) manufacturers and suppliers, welcome to wholesale our products at good price from our factory.

600/1000V XLPE Insulated, PVC Sheathed, Double steel tape armoured Power Cables (3 Cores)

CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2

Application:

The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.

STANDARDS:

Basic design adapted to IEC 60502-1

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)**

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

VOLTAGE RATING

600/1000V

CABLE CONSTRUCTION

Conductor: Plain annealed copper wire, normal stranded or compact stranded according to IEC(EN) 60228 class 2.

Insulation: Extruded cross-linked XLPE compound.

Filler, binder and inner covering: PP, PET, PVC

Armouring: Double steel tape

Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

COLOUR CODE

Insulation Colour as per BS7671


With Earth Conductor

Without Earth Conductor

2Cores

-

Brown, Blue

3Cores

Yellow/Green, Brown, Blue

Brown, Gray, Black

4Cores

Yellow/Green, Brown, Gray, Black

Brown, Gray, Black, Blue

5Cores

Yellow/Green, Brown, Gray, Black, Blue

Brown, Gray, Black, Blue, Black

Above 5 Cores

Yellow/Green, Black Numbered

Black Numbered

Sheath Colour: Black (other colors upon request)

Physical AND THERMAL PROPERTIES

Temperature range during operation: Max.90°C for XLPE

250°C in short-circuit for 5secs max.

Minimum bending radius: 10x Overall Diameter

CONSTRUCTION PARAMETERS

Conductor


No. of Core X Cross Section

Phases

Neutral

Nominal Diameter Overall Conducrtor

Nominal Insulation Thickness

Nominal Steel Tape Thickness

Nominal Sheath Thickness

Nominal Overall Diatemer

Approx. No./ Weight

No./ Weight Nominal Diameter of Strands

No./ Nominal Diameter of Strands

Pha.

Neu.

Pha.

Neu.

mm2

No/mm

No/mm

mm

mm

mm

mm

mm

mm

mm

Kg/km

3x10+1x6

7/1.35

7/1.04

3.75

2.90

0.7

0.7

0.2

1.8

20.1

740

3x16+1x10

7/1.70

7/1.35

4.75

3.75

0.7

0.7

0.2

1.8

22.5

1,004

3x25+2x16

7/2.14

7/1.70

5.85

4.75

0.9

0.7

0.2

1.8

25.8

1,421

3x35+1x16

7/2.52

7/1.70

6.90

4.75

0.9

0.7

0.2

1.8

27.7

1,745

3x35+1x25

7/2.52

7/2.14

6.90

5.85

0.9

0.9

0.2

1.8

28.6

1,864

3x50+1x25

19/1.78

7/2.14

8.15

5.85

1.0

0.9

0.2

1.8

31.3

2,358

3x50+1x35

19/1.78

7/2.52

8.15

6.90

1.0

0.9

0.2

1.9

32.0

2.72

3x70+1x35

19/2.14

7/2.52

9.75

6.90

I.1

0.9

0.2

2.0

35.9

3166

3x70+1x50

19/2.14

19/1.78

9.75

8.15

I.1

1.0

0.2

2.0

36.8

3.341

3x95+1x50

19/2.52

19/1.78

11.4

8.15

I.1

1.0

0.5

2.1

41.4

4,611

3x120+1x70

37/2.03

19/2.14

12.8

9.75

1.2

I.1

0.5

2.3

45.6

5682

3x150+1x95

37/2.25

19/2.52

14.3

11.4

1.4

I.1

0.5

2.4

50.8

7,072

3x150+1x120

37/2.25

37/2.03

14.3

12.8

1.4

1.2

0.5

2.5

51.8

7,357

3x185+1x95

37/2.52

19/2.52

15.9

11.4

1.6

I.1

0.5

2.6

54.7

8,348

3x185+1x120

37/2.52

37/2.03

15.9

12.8

1.6

1.2

0.5

2.6

55.8

8638

3x240+1x120

61/2.25

37/2.03

18.2

12.8

1.7

1.2

0.5

2.7

61.0

10,660

3x240+1x150

61/2.25

37/2.25

18.2

14.3

1.7

1.4

0.5

2.8

62.2

11024

3x300+1x150

61/2.52

37/2.25

20.4

14.3

1.8

1.4

0.5

2.9

66.8

12,809

3x300+1x185

61/2.52

37/2.52

20.4

15.9

1.8

1.6

0.5

3.0

68.1

13,256

Notes:

1) *All conductors in accordance with lEC 60228. Compact shape (Com.) or non-compact depending on order.

2) Beside above list we can also provide others size depend on customer's requirement.

Electrical Properties

No. of Core X Cross Section

Conductor

Max.DC resistance of conductor @20°C

Phases

Neutral

Dia.Overall Conducrtor

No./Nominal Diameter of Strands

No./Nominal Diameter of Strands

Pha.

Neu.

Pha.

Neu.

mm2

No/mm

No/mm

mm

mm

Ω/km

Ω/km

3x10+1x6

7/1.35

7/1.04

3.75

2.90

1.83

3.08

3x16+1x10

7/1.70

7/1.35

4.75

3.75

1.15

1.83

3x25+2x16

7/2.14

7/1.70

5.85

4.75

0.727

1.15

3x35+1x16

7/2.52

7/1.70

6.90

4.75

0.524

1.15

3x35+1x25

7/2.52

7/2.14

6.90

5.85

0.524

0.727

3x50+1x25

19/1.78

7/2.14

8.15

5.85

0.387

0.727

3x50+1x35

19/1.78

7/2.52

8.15

6.90

0.387

0.524

3x70+1x35

19/2.14

7/2.52

9.75

6.90

0268

0.524

3x70+1x50

19/2.14

19/1.78

9.75

8.15

0268

0.387

3x95+1x50

19/2.52

19/1.78

11.4

8.15

0.193

0.387

3x120+1x70

37/2.03

19/2.14

12.8

9.75

0.153

0.268

3x150+1x95

37/2.25

19/2.52

14.3

11.4

0.124

0.193

3x150+1x120

37/2.25

37/2.03

14.3

12.8

0.124

0.153

3x185+1x95

37/2.52

19/2.52

15.9

11.4

0.0991

0.193

3x185+1x120

37/2.52

37/2.03

15.9

12.8

0.0991

0.153

3x240+1x120

61/2.25

37/2.03

18.2

12.8

0.0754

0.153

3x240+1x150

61/2.25

37/2.25

18.2

14.3

0.0754

0.124

3x300+1x150

61/2.52

37/2.25

20.4

14.3

0.0601

0.124

3x300+1x185

61/2.52

37/2.52

20.4

15.9

0.0601

0.0991

Electrical PROPERTIES

Conductor Operating Temperature : 90°C

Ambient Temperature : 30°C

Current-Carrying Capacities (Amp)

Conductor crosssectional area

Reference Method 1 (clipped direct)

Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )

In single-way ducts

Laid direct in ground

one 2-core cable single phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

one 2-core cable single phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

one 2-core cable single phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

one 2-core cable single phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

1

2

3

4

5

6

7

8

9

mm2

A

A

A

A

A

A

A

A

10

85

73

90

78

-

65

-

80

16

110

94

115

99

115

94

140

115

25

146

124

152

131

145

125

180

150

35

180

154

188

162

175

150

215

180

50

219

187

228

197

210

175

255

215

70

279

238

291

251

260

215

315

265

95

338

289

354

304

310

260

380

315

120

392

335

410

353

355

300

430

360

150

451

386

472

406

400

335

480

405

185

515

441

539

463

455

380

540

460

240

607

520

636

546

520

440

630

530

300

698

599

732

628

590

495

700

590

Voltage Drop (Per Amp Per Meter)

Conductor cross-sectional area

2-core cable d.c.

2 cables, single-phase a.c.

3 or 4 cables, 3-phase a.c.

2 cables, single- phase a.c.

3 or 4 cables, 3-phase a.c.

In ducts or in ground

In ducts or in ground

1

2

3

4

5

6

mm2

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

6

7.9

7.9

6.8

7.9

6.5

10

4.7

4.7

4.0

4.7

3.9

16

2.9

2.9

2.5

2.9

2.6



r

x

z

r

x

z



25

1.850

1.350

0.160

1.900

1.600

0.140

1.650

1.900

1.600

35

1.350

1.350

0.155

1.350

1.150

0.135

1.150

1.350

1.200

50

0.980

0.990

0.155

1.000

0.860

0.135

0.870

1.000

0.870

70

0.670

0.670

0.150

0.690

0.590

0.130

0.600

0.690

0.610

95

0.490

0.500

0.150

0.520

0.430

0.130

0.450

0.520

0.450

120

0.390

0.400

0.145

0.420

0.340

0.130

0.370

0.420

0.360

150

0.310

0.320

0.145

0.350

0.280

0.125

0.300

0.350

0.300

185

0.250

0.260

0.145

0.290

0.220

0.125

0.260

0.290

0.250

240

0.195

0.200

0.140

0.240

0.175

0.125

0.210

0.240

0.210

300

0.155

0.160

0.140

0.210

0.140

0.120

0.185

0.210

0.190

400

0.120

0.130

0.140

0.190

0.115

0.120

0.165

0.190

0.180